Hygiene Coatings
Search  Go 
PRODUCT TECHNICAL INFORMATION for Hygiene Coatings Printer Friendly Version
Material Description Colour † Vol Solids % EC
SED gm/kg
Typical Thickness (microns) Time (hrs) @ 15°C App
Method
††
Flash Point °C Weight Kg/Ltr Cleanser Thinner
Dry Wet Pot
Life
Recoat Handling
Biogard M630V2
Hygiene Coating
LR 50 0 75 150 2.5 24 24 A, B, R >55 1.34 Water
Epigrip C400V3
Zinc Phosphate Primer/ Buildcoat
LR 70 190 75 107 2.5 5 15 A,C,B,R 24 1.57 9/2
Epigrip M902
Winter fast Hi-Build Aluminium Primer
Alum-
inium
75 206 100 133 4 5 12 A,B 30 1.18 5
Leighs L703 Mordant Wash Blue Solu-
tion
919 N/A N/A N/A 3 3 B 24 0.99 Water

EC SED = EC Solvent Emissions Directive - values quoted are grams of VOC per kilo of mixed material.

LR = Limited Range

†† A = Airless Spray, C = Conventional Spray, H = Heavy Duty Spray, B = Brush, R = Roller

NB - Spreading rate depends on porosity of the substrate and the method of application.

For Actual Thickness details consult the specification required.
The information detailed is liable to modification, please consult the latest Technical Data Sheet available on our web site or contact Leighs Customer Service Department.

May 06 - Issue 5












Website Disclaimer | Terms & Conditions of Business | Privacy Policy | Site Map | Contact Us

Leighs Paints   Registered in England   Reg Number: 893081   Reg Office: Tower Works, Kestor Street, Bolton BL2 2AL England