| G10 |
| 650 |
SITE PAINTING OF EXTERNALLY EXPOSED EXISTING PAINTED STEELWORK WITH A TWO PACK EPOXY PRIMER AND INTERMEDIATE COAT AND A URETHANE FINISH |
|
| Life to first Maintenance: |
Up to 10 years |
| Use/location |
Existing painted external steelwork |
| Paint manufacturer |
Leighs Paints, Tower Works, Kestor Street, Bolton BL2 2AL Tel: +44(0)1204 521771   Fax: +44 (0)1204 534015 |
| Preparation |
Areas of damage which exhibit surface rusting shall be prepaed by scraping/wire brushing to ensure all residual rust is removed to BS EN ISO 8501-1:2001, preparation grade St3. Surrounding paint coatings shall be removed back to a firm sound edge and then feathered over a distance of 50mm in the region of the affected area |
Spot primer - Dry film thickness - Colour - Special requirements |
Epigrip M902 Winterfast hi-build brushing aluminium To original dry film thickness Aluminium Apply by brush |
Site intermediate coat - Dry film thickness - Colour |
Epigrip M905 Winterfast hi-build undercoat 100 microns as defined in BS EN ISO 12944-5 Light grey, off white |
Site finishing coat - Dry film thickness - Colour - Special requirments |
Resistex C137V2 Special finish 50 microns nominal as defined in BS EN ISO 12944-5 As required by the architect Alternatively Resistex C237 sheen finish can be specified |